Metrol Technology Group
Image

The Metrol T.R.I.C.S /PARAGON OCULUS “Talking” Quartz Gauge

Oculus Technology - “20/20 Vision Downhole”

Specifications

MWP:
10,000psi, 16,000psi or 20,000psi, 25,000psi (on request)

Temperature range:
-20°C to 150°C (-4°F to 300°F)

Memory capacity:
3.5 million data sets

Accuracy:
± 0.025% of full scale (± 2.5psi on 10,000psi gauge), +1°C

Resolution:
pressure (typical) 0.0008 psi (@ 1 second sample duration)– temperature: 0.002°C

Paragon download resolution is selectable at download typically data is downloaded at ¼ of the full resolution to optimise data compressibility.

Length:
122cm (48”)
31.8mm (1.25”)

Weight:
3kg (6.6lbs)

Sample Rates:
0.03125 second to 256 seconds (Fully programmable)

Sample Duration:
0.03125 second to 2 seconds (programmable)

Duration:
Up to 7 years (dependant on temperature)

T.R.I.C.S./Paragon Adapter:
Allowing wireline and acoustic data retrieval, and the facility to re-programme the gauge.

Overpressure Limits